| Business Type | Manufacturer Exporter Government |
| Company Address | shanghai china |
| Business Category | Electronics & Electrical » Electromechanical Components » Acoustic Components |
| Post Date | Jul 15, 2008 |
| Validity Date | Jun 30, 2018 |
NDB
l Pulse width modulation (PWM), Class D amplifiers, Power synthesiger.
l Output power: 100W/200W, adjustable.
l Frequency range:150~800KHz 1KHz frequency
channel spacing, Frequency synthesizer.
l Frequency stability: better than 0.005%.
l Automatic antenna tuning.
l Two identical channel in single cabinet, One operating and one stand by, Automatic switch over.
l 2 lines remote control and monitoring, no attendance operation.
l Ambient temperature:-25~+
l AC or DC power supply, switch power supply technology.
AC power requirement: 220V, 50Hz,
DC power requirement: 48V,
Technical Specifications
1、 Frequency range 150kHz~800kHz.
2、 Channel 651 channels (frequency interval 1 KHz).
3、 Frequency tolerance ±50×10-6 of nominal.
4、 Output Power 100W, 200W Continuingly adjustable on the rating output power range.
5、
6、 Amplitude modulation audio 1020Hz±50Hz.
7、
8、 There are five working states: Auto-amplitude-modulation message(auto-tone-keying), auto-equiamplitude message (auto-carrier-keying), manual-amplitude modulation message (manual-tone-keying), manual-equiamplitude message(manual-carrier-keying), amplitude modulation word(voice modulation). There are five working modes: unit A service 、unit B service、A service & B standby、B service & A standby and remote control.
9、 Remote Control
Remote control turning on and turning off, remote control working mode choosing, remote inspect the identification code, RF output, power supply alarm signals of NDB.
Remote control use a pair of 600W telephone line, when loop resistance £2kW, effect distance³
10、 Dual-machine Automatic changeover
Machine A&B can automatically change from host machine to standby machine. When output power descend 3dB, or power failure, host machine out of service and standby machine automatic start service, while Remote control unit will also emit sound and light alarm in the event of alarm or failure condition.
11、 Carrier harmonic level £-50dBc.
12、
Resistance: 5W~25W;
Capacitance: 300pF~1200pF(exclude 50pF distributing capacitance).
Automatic tune to resonance when output power descends to 70% caused by antenna mistuning
14.. Power Supply Requirement
AC: 220V+10-15%, 50Hz single-phase. When RF power output is 200W, current does not exceed
DC: 48V battery, when RF power output is 200W, current does not exceed
15、 Ambient Temperature
Working temperature: -
Storing temperature: -
Relative Humidity Up to 95±3%(+
16、Working Hours 24h continuous work.
17、Storing period of equipment One year
| Place of Origin | Currency | ||
| Payment Method | Minimum Order | ||
| Delivery Time | Delivery | ||
| Packaging | Supply Ability |